Noise Measuring Sensor for Smart Cities
TA120

Noise has become an essential vector when sensing smart cities. CESVA’s more than 45 years of experience designing and manufacturing sound level meters are concentrated in the TA120 noise measuring sensor.
The TA120 combines the accuracy of a Class 1 sound level meter, maximum protection of a professional outdoor kit (rain, snow, wind, dust, birds, IP65), and full connectivity with major open source platforms and industrial protocols into one small-sized single piece of equipment.
The TA120 requires minimal annual maintenance and can be verified with an acoustic calibrator (IEC 60942). The TA120 offers you high precision and reliable noise measurements.

Product Full Description

The TA120 brings together in a small-sized single piece of equipment, the accuracy of a Class 1 sound level meter, maximum protection of a professional outdoor kit (rain, snow, wind, dust, birds, IP65), and full connectivity with major open source platforms and industrial protocols.

The TA120 requires minimal annual maintenance and can be verified with an acoustic calibrator (IEC 60942). The TA120 offers you high precision and reliable noise measurements.

Applications:

  • Smart Cities sensing
  • Noise surveillance networks (permanent monitoring):
    Road and port infrastructures
    Industrial activities
    Separate waste collection routes
    Control of Works
  • Noise monitoring:
    Concerts, festivals, major events and exhibitions
    Sports events and racetracks
    Quiet areas (acoustically protected)
  • Generating noise maps and displaying in real time noise levels

Features:

  • Class 1 precision sensor according to IEC 61672-1.
  • Protection against external agents with an outdoor kit: wind, rain and birds. Keeps class 1 precision. IP65 protection.
  • Can be fully integrated into different platforms: NoisePlatform (CESVA), open source ones such as Sentilo or proprietary platforms like Telefónica or Smarty Planet.
  • Light weighted small sized and easy to install in street lights, marquees, billboards, shelters, kiosks and advertising posts.
  • Powered by mains, POE (Power over Ethernet), 12 VDC (Solar panels*, external batteries).
  • Continuous measurement 24 h/7 days a week.
  • Minimum annual maintenance. Materials used in the manufacture of TA120 ensure a long life.
  • Removable outdoor kit for quick verification and adjustment with an acoustic calibrator (IEC 60942).
  • Network with an unlimited number of sensors.
  • Communication by Ethernet (RJ45), Wi-Fi*, 2G/ GPRS or 3G modem*, 4-20 mA loop*.

Technical Specifications

Noise Measurement According to IEC 61672.

Detector
Equivalent continuous sound level and Fast and Slow time-weighted sound level.
Frequency Weighting
A and C
Measured Function
Equivalent level with frequency weighting A and C with programable integration time from 1s to 60 min: LAeqT, LCeqT. Maximum time-weighted level with fast and slow time weighting over a programable time from 1s to 60 min with frequency weighting A: LAFmaxT, LASmaxT
Resolution
0.1 dB
Accuracy according to IEC 61672-1
Class 1
Measurement Single Range from noise
28 to 120 dBA
Linearity Range at 1kHz
35 to 120 dBA
Measurement Single Range from noise
35 to 120 dBC
Linearity Range at 1kHz
42 to 120 dBC
Acoustic Verification
With acoustic calibrator (IEC 60942)

Microphone

Type
½” condenser microphone
Polarization
0 V
Nominal Sensitivity
25.0 mV/Pa

Protection against external agents

Outdoor kit
Protection against rain, snow, wind and birds
Degree of protection provided by the enclosure
IP65

Connectivity

USB Communication for Configuration
Type: Digital complies with USB rev. 2.0 (type B)
Ethernet Communication for data transmission
Port: RJ45, 10/100 Mbps
4-20 mA Current Loop
CL120 Module* required || Type: Analog (*see options on the Cesva website)
2G/GPRD or 3G Communication for data transmission
MR120 Module* or MR123 Module* required (micro SIM) (*see options on the Cesva website)
Wi-Fi Communication for data transmission
WF120 module required* (*see options on the Cesva website)

Transmission Protocols

Protocol
HTTP, HTPPS (secure connection)
IP Address
Dynamic (DHCP) and Static
Format
Sentilo JSON, Ultralight 2.0, Others (consult)

Full Data Sheet

For access to the full data sheet, go to Cesva - TA120
Information on technical characteristics is based on the latest information available at the time of publication.